UNITY

Medical device: Phacoemulsification system handpiece. 5 companies paid 1,933 providers $1.02M in 2025 payments naming it.

  • Medical device
  • Paid for by Alcon Vision Llc, Alcon Research Llc +3
  • FDA Class 2
Paid to providers, 2025 $1.02M 3,812 payments to 1,933 providers
Device problem reports 1,581 2 deaths, 279 injuries (FDA MAUDE)
Companies paying for it 5 in 2025 payments

Companies paying for it (2025)

Safety record

  • FDA recalls naming it5
  • Device problem reports1,581
  • FDA risk classClass 2 (moderate)

Reports to FDA don't prove the product caused the event.

About this device

A holder for a dedicated detachable tip that together become a unit that delivers energy (e.g., ultrasonic, piezoelectric), provided from a system generator, to perform phacoemulsification (a procedure for the liquefying and removal of the opaque lens nucleus in cataract surgery). This device will be activated by the surgeon using a foot control and may provide or facilitate the irrigation/suction systems needed for the removal of debris. The handpiece typically designed in the form of a pen or pencil. This is a reusable device.

Brand
UNITY
Company
Alcon Laboratories, Inc.
Model described
UNITY U/S HP (00380650003157)
Device type
Phacoemulsification system handpiece
FDA product code
HQC · Unit, Phacofragmentation
FDA class
Class 2 (moderate risk)
Specialty
Ophthalmic
Sold
by prescription
Status
In Commercial Distribution
GUDID record
00380650003157

FDA's device database (GUDID) record of the device identifier named most in the payments: one model of the product line.

FDA recalls

5 recalls naming it since 2004 (Class I, the most serious: 0; Class II: 5; Class III: 0).

The newest FDA recalls naming the product
StartedRecallClassFirmProductReason
2025-08-05Z-0308-2026Class IIAlcon Research LLC Brand Name: Alcon Laboratories, Inc. Product Name: Accessory devices for Unity and Constellation surgical consoles Model/Catalog Number: Many - See 'Attachment 1 - Affected Product List' 8065000356 27GA HP ENTRY SYSTEM, 4 MM 1 COUNT …Due to incomplete seals in the pouch which provide the sterile barrier.
2025-08-05Z-0307-2026Class IIAlcon Research LLC Brand Name: Alcon Laboratories, Inc. Product Name: Accessory devices for Unity and Constellation surgical consoles Model/Catalog Number: Many - See 'Attachment 1 - Affected Product List' 8065000252 UNITY 27 GA CHANDELIER …Due to incomplete seals in the pouch which provide the sterile barrier.
2025-08-05Z-0306-2026Class IIAlcon Research LLC Brand Name: Alcon Laboratories, Inc. Product Name: Accessory devices for Unity and Constellation surgical consoles Model/Catalog Number: Many - See 'Attachment 1 - Affected Product List' 8065000393 UNITY HP VISCOUS FLUID CONTROL VFC PACK …Due to incomplete seals in the pouch which provide the sterile barrier.
2025-08-05Z-0305-2026Class IIAlcon Research LLC Brand Name: Alcon Laboratories, Inc. Product Name: Accessory devices for Unity and Constellation surgical consoles Model/Catalog Number: Many - See 'Attachment 1 - Affected Product List' 8065750918 PAK,I/A LINE,NGVS …Due to incomplete seals in the pouch which provide the sterile barrier.
2025-08-05Z-0304-2026Class IIAlcon Research LLC Brand Name: Alcon Laboratories, Inc. Product Name: Accessory devices for Unity and Constellation surgical consoles Model/Catalog Number: Many - See 'Attachment 1 - Affected Product List' 8065000250 UNITY 27+DS HYPERVIT 30K VIT PROBE …Due to incomplete seals in the pouch which provide the sterile barrier.

From FDA enforcement reports that name this device, by a company paying for it. Class I is the most serious recall and Class III the least.

The full lists, detailed tables and downloads are in the Data view.