MICRA

Medical device: Intracardiac pacemaker. 1 company paid 4,025 providers $926K in 2025 payments naming it.

  • Medical device
  • Paid for by Medtronic, Inc.
  • FDA Class 3
Paid to providers, 2025 $926K 12,130 payments to 4,025 providers
Device problem reports 15,779 1,197 deaths, 6,606 injuries (FDA MAUDE)
Companies paying for it 1 in 2025 payments

Companies paying for it (2025)

Safety record

  • FDA recalls naming it2
  • Device problem reports15,779
  • FDA risk classClass 3 (highest)

Reports to FDA don't prove the product caused the event.

About this device

A battery-powered, hermetically-sealed pulse generator impregnated with a steroid (e.g., dexamethasone) intended to be implanted with a catheter, via transvenous access, into the right ventricle (i.e., single-chamber pacing) of an arrhythmic heart to generate/conduct electrical impulses to improve cardiac output. It contains sensors to detect changes in the body (e.g., motion, breathing frequency) and to adjust the pacing rate accordingly (rate-responsive). Wireless telemetry with external devices enables programming adjustments and may allow on-going heart monitoring; it does not provide …

Brand
Micra™
Company
MEDTRONIC, INC.
Model described
TPS MC1VR01US MICRA US SCALABLE (MC1VR01US)
Device type
Intracardiac pacemaker
FDA product code
PNJ · Leadless pacemaker
FDA class
Class 3 (highest risk)
Specialty
Cardiovascular
Sold
by prescription
Implant
Yes
Status
In Commercial Distribution
GUDID record
00643169711761

FDA clearance or approval

Premarket decisions the device cites
NumberKindDeviceApplicantDecided
P150033PMAMEDTRONIC MICRA TRANSCATHETER PACEMAKER SYSTEMMedtronic, Inc. 2016-04-06

A 510(k) clearance means FDA found the device much like one already sold. A PMA approval means FDA reviewed clinical evidence, which it requires for high-risk devices.

FDA's device database (GUDID) record of the device identifier named most in the payments: one model of the product line.

FDA recalls

2 recalls naming it since 2004 (Class I, the most serious: 0; Class II: 2; Class III: 0).

The newest FDA recalls naming the product
StartedRecallClassFirmProductReason
2025-06-17Z-2128-2025Class IIMedtronic, Inc. Medtronic SmartLink software loaded on CareLink SmartSync Device Manager, Model Number 24967A with the following software components: 1. Azure Astra application, Software Model Number D00U003; 2. Percepta Serena Solara application, …A software update for Medtronic CareLink SmartSync Device Manager (SmartSync) is now available. The update eliminates the potential display of an erroneous electrical reset (pop-up) message upon interrogation with a SmartSync Device …
2025-06-17Z-2127-2025Class IIMedtronic, Inc. Medtronic SmartLink Software loaded on SmartSync Patient Connector, Model Number 24967 with the following software components: 1. Azure Astra application, Software Model Number D00U003; 2. Percepta Serena Solara application, Software …A software update for Medtronic CareLink SmartSync Device Manager (SmartSync) is now available. The update eliminates the potential display of an erroneous electrical reset (pop-up) message upon interrogation with a SmartSync Device …

From FDA enforcement reports that name this device, by a company paying for it. Class I is the most serious recall and Class III the least.

The full lists, detailed tables and downloads are in the Data view.