Integra

Medical device: Animal-derived wound matrix dressing. 2 companies paid 7,974 providers $4.62M in 2025 payments naming it.

  • Medical device
  • Paid for by Integra Lifesciences Corporation, Smith+Nephew, Inc.
  • FDA Class U
Paid to providers, 2025 $4.62M 40,538 payments to 7,974 providers
Device problem reports 4,628 13 deaths, 469 injuries (FDA MAUDE)
Companies paying for it 2 in 2025 payments

Companies paying for it (2025)

Safety record

  • FDA recalls naming it68
  • Device problem reports4,628
  • FDA risk classClass U

Reports to FDA don't prove the product caused the event.

About this device

A bioabsorbable animal-derived protein matrix [e.g., peptides derived from collagen] designed to provide: 1) a matrix of structural proteins and/or 2) a skin template of living cells [fibroblasts], to facilitate the infiltration/attachment of native cells/tissues (e.g., blood vessels) for wound/skin healing. It is available in various forms [e.g., solution, powder, occlusive/semi-occlusive cover (non-oral)] and may include additional compounds (e.g., alginate, fatty acids). It may be intended to be covered with a secondary dressing. It is commonly intended for treating partial- and …

Brand
Integra®
Company
Integra Lifesciences Corporation
Model described
Integra® MESHED BILAYER WOUND MATRIX 8 in*10 in (20 cm*25 cm) (MWM8101)
Device type
Animal-derived wound matrix dressing
FDA product code
FRO · Dressing, wound, drug
FDA class
Class U
Specialty
Unknown
Sold
by prescription
Status
In Commercial Distribution
GUDID record
10381780032397

FDA clearance or approval

Premarket decisions the device cites
NumberKindDeviceApplicantDecided
K081635510(k)INTEGRA MESHED BILAYER WOUND MATRIXIntegra Lifesciences Corp. 2008-12-04

A 510(k) clearance means FDA found the device much like one already sold. A PMA approval means FDA reviewed clinical evidence, which it requires for high-risk devices.

FDA's device database (GUDID) record of the device identifier named most in the payments: one model of the product line.

FDA recalls

68 recalls naming it since 2004 (Class I, the most serious: 0; Class II: 68; Class III: 0).

The newest FDA recalls naming the product
StartedRecallClassFirmProductReason
2024-01-19Z-1203-2024Class IIIntegra LifeSciences Corp. Ref No: INSHITHRZN / Integra Cranial Access Kit. For access to the subarachnoid space or the lateral ventricles of the brain.A defect in the sterile packaging (header bag) of the Cranial Access Kit failing the required packaging integrity testing criteria. Therefore, product sterility maybe compromised.
2024-01-19Z-1197-2024Class IIIntegra LifeSciences Corp. Ref No: INS7250 / Integra Cranial Access Kit. For access to the subarachnoid space or the lateral ventricles of the brain.A defect in the sterile packaging (header bag) of the Cranial Access Kit failing the required packaging integrity testing criteria. Therefore, product sterility maybe compromised.
2024-01-19Z-1196-2024Class IIIntegra LifeSciences Corp. Ref No: INS5HND / Integra Cranial access kit (without Prep solutions) Bit and Guard. For access to the subarachnoid space or the lateral ventricles of the brain.A defect in the sterile packaging (header bag) of the Cranial Access Kit failing the required packaging integrity testing criteria. Therefore, product sterility maybe compromised.
2024-01-19Z-1195-2024Class IIIntegra LifeSciences Corp. Ref No: HITHSP06 / Integra Cranial Access Kit. For access to the subarachnoid space or the lateral ventricles of the brain.A defect in the sterile packaging (header bag) of the Cranial Access Kit failing the required packaging integrity testing criteria. Therefore, product sterility maybe compromised.
2024-01-19Z-1194-2024Class IIIntegra LifeSciences Corp. Ref No: HITHSP04 / Integra Cranial Access Kit. For access to the subarachnoid space or the lateral ventricles of the brain.A defect in the sterile packaging (header bag) of the Cranial Access Kit failing the required packaging integrity testing criteria. Therefore, product sterility maybe compromised.
2023-10-19Z-0498-2024Class IIIntegra LifeSciences Corp. Integra Cranial Access Kit-For access to the subarachnoid space or the lateral ventricles of the brain. Catalog Number: HITHSP04Defect in the outer packaging of the Cranial Access Kits. can cause the packaging to split without any additional forces outside compromising the sterility of the device
2023-10-19Z-0496-2024Class IIIntegra LifeSciences Corp. Integra Cranial Access Kit- For access to the subarachnoid space or the lateral ventricles of the brain. Catalog Number: INS7250Defect in the outer packaging of the Cranial Access Kits. can cause the packaging to split without any additional forces outside compromising the sterility of the device
2023-10-19Z-0495-2024Class IIIntegra LifeSciences Corp. Integra Cranial Access Kit-For access to the subarachnoid space or the lateral ventricles of the brain. Catalog Number: INS7260Defect in the outer packaging of the Cranial Access Kits. can cause the packaging to split without any additional forces outside compromising the sterility of the device
2023-10-19Z-0493-2024Class IIIntegra LifeSciences Corp. Integra Cranial Access Kit - For access to the subarachnoid space or the lateral ventricles of the brain. Catalog Number: INS7040Defect in the outer packaging of the Cranial Access Kits. can cause the packaging to split without any additional forces outside compromising the sterility of the device
2023-10-19Z-0492-2024Class IIIntegra LifeSciences Corp. Integra Cranial Access Kit -For access to the subarachnoid space or the lateral ventricles of the brain. Catalog Number: INS7270Defect in the outer packaging of the Cranial Access Kits can cause the packaging to split without any additional forces outside compromising the sterility of the device
2023-10-19Z-0491-2024Class IIIntegra LifeSciences Corp. Integra Cranial access kit (without Prep solutions) Bit and Guard-For access to the subarachnoid space or the lateral ventricles of the brain. Catalog Number: INS5HNDDefect in the outer packaging of the Cranial Access Kits can cause the packaging to split without any additional forces outside compromising the sterility of the device
2022-02-28Z-0906-2022Class IIIntegra LifeSciences Corp. Integra Universal Flexible Arm part number REF 1362275Excess force used to tighten the Universal Flexible Arm can cause the internal cable to break at the tip, resulting in an unusable condition.
2022-01-04Z-0548-2022Class IISmith & Nephew, Inc. INTEGRA SURFIX ALPHA Screwdriver Torx 10, REF 219 135 NDThe affected screwdrivers are out of specification and may not mate with the Surfix Alpha Lock screw
2020-08-04Z-2955-2020Class IIIntegra LifeSciences Corp. Integra Padgett Electric Dermatome Set - Product Usage: are intended for use in the cutting of skin grafts for use in plastic surgery and/or burn treatment. These instruments are intended only for professional use in hospitals and similar …lntegra LifeSciences has identified through a number of complaints that the handpiece cable melts following sterilization.
2020-08-04Z-2954-2020Class IIIntegra LifeSciences Corp. Integra Padgett Dermatome Set - Product Usage: are intended for use in the cutting of skin grafts for use in plastic surgery and/or burn treatment. These instruments are intended only for professional use in hospitals and similar medical …lntegra LifeSciences has identified through a number of complaints that the handpiece cable melts following sterilization.
2019-08-07Z-2435-2019Class IIIntegra LifeSciences Corp. Integra Jarit GEMINI CLAMP 9 1/4 inch - used in vascular and cardiothoracic procedures used for clamping and occluding vessels. Cat. #140-332A small crack at the box lock corner may after multiple cleaning and sterilization cycles produce an increased risk of corrosion, weakening the instrument and resulting in premature need for replacement and/or breakage of the instrument
2017-01-20Z-1192-2017Class IIIntegra LifeSciences Corp. Integra Cadence Total Ankle SystemPosterior tibial fractures have been reported.
2016-08-23Z-2910-2016Class IIIntegra LifeSciences Corp. Integra Lumbar Drainage Set, REF 910120A, Sterile EO, Rx only, primary packaged in a PVC blister sealed with Tyvek sheet and secondary packaged in to Tyvek pouch. External drainag system is primary packaged in a Tyvek pouch and secondary …During final sampling inspection, one of the lots was discovered with a total incomplete packaging seal of the sterile product.
2016-08-23Z-2909-2016Class IIIntegra LifeSciences Corp. Integra Ventricular Catheter Accessory Kit, REF 951303, Sterile EO, Rx only, packaged in a PVC tray, then secondary package in to Tyvek pouch and tertiary packaged in to Tyvek pouch. Sealed pouches are packaged in a cardboard box. F8 35cm …During final sampling inspection, one of the lots was discovered with a total incomplete packaging seal of the sterile product.
2016-08-23Z-2908-2016Class IIIntegra LifeSciences Corp. Integra Drainage Accessory Kits, REF 910122, Sterile EO, Rx only, packaged in one Tyvek pouch. Five (5) sealed Tyvek pouches are packaged in a cardboard box. Used for Intraoperative drainage of CSFDuring final sampling inspection, one of the lots was discovered with a total incomplete packaging seal of the sterile product.

From FDA enforcement reports that name this device, by a company paying for it. Class I is the most serious recall and Class III the least.

The full lists, detailed tables and downloads are in the Data view.