HARMONY
Medical device: Pulmonary transcatheter heart valve bioprosthesis. 2 companies paid 401 providers $1.28M in 2025 payments naming it.
- Medical device
- Paid for by Medtronic, Inc., Steris Corporation
- FDA Class f
Companies paying for it (2025)
- MEDTRONIC, INC.$1.28M
- STERIS CORPORATION$2,483
Safety record
- FDA recalls naming it4
- Device problem reports920
- FDA risk classClass f
Reports to FDA don't prove the product caused the event.
About this device
An implantable xenograft (e.g., bovine, porcine) intended to be used to repair/replace a stenosed or regurgitant pulmonary heart valve prosthesis (previously implanted), or native pulmonary valve anatomy that may have been surgically repaired, and which is designed to be implanted with a catheter via vascular access. It may be attached to an expandable metal framework which may be expanded with a balloon or self-expand, and may include other material types (e.g., synthetic polymer). Devices associated with implantation (e.g., catheter, introducer) may be included.
- Brand
- Harmony™
- Company
- MEDTRONIC, INC.
- Model described
- TPV HARMONY-25 COMM (HARMONY-25)
- Device type
- Pulmonary transcatheter heart valve bioprosthesis
- FDA product code
- NPV · Pulmonary valve prosthesis percutaneously delivered
- FDA class
- Class f
- Specialty
- Unknown
- Sold
- —
- Implant
- Yes
- Status
- In Commercial Distribution
- GUDID record
- 00763000338992
FDA clearance or approval
| Number | Kind | Device | Applicant | Decided |
|---|---|---|---|---|
| P200046 | PMA | Harmony TPV System | Medtronic, Inc. | 2021-03-26 |
A 510(k) clearance means FDA found the device much like one already sold. A PMA approval means FDA reviewed clinical evidence, which it requires for high-risk devices.
FDA's device database (GUDID) record of the device identifier named most in the payments: one model of the product line.
FDA recalls
4 recalls naming it since 2004 (Class I, the most serious: 1; Class II: 3; Class III: 0).
| Started | Recall | Class | Firm | Product | Reason |
|---|---|---|---|---|---|
| 2022-03-02 | Z-0927-2022 | Class I | Medtronic Inc | Harmony Delivery Catheter System. Part of the Harmony Transcatheter Pulmonary Valve (TPV) Replacement Implantation System. | There is potential for the capsule bond to break during the procedure. |
| 2016-10-05 | Z-0746-2017 | Class II | Steris Corporation | Harmony Insight Diagnostic Monitor Support System - 100 Spring Arm (EMS) The system is intended for use in surgical operating rooms (OR) or intraoperative surgical/imaging rooms where simultaneous multiple image viewing is required | The Drager Pendula spring arm device has a set of screws located on the spring arm that were not properly secured with Loctite and may become loose. |
| 2014-04-04 | Z-1850-2014 | Class II | Steris Corporation | Vertical Spring Arm for Single or Dual Monitor Mount (Harmony LL 500 and Harmony LL 700 surgical lighting systems), Steris Corporation. Model numbers YG19051 and YG19262. | Potential for the welded seam in affected monitor spring arms to crack and/or break. |
| 2013-08-15 | Z-0141-2014 | Class II | Steris Corporation | Harmony Equipment Management System, Model #603X/80XX, STERIS Corporation, Mentor, OH Harmony Equipment Management Systems (EMS) are used in hospital facilities to provide ready access to medical gasses, electrical power and audio/visual … | Dr¿ger Medical GmbH has notified STERIS of the potential for a break in the drive screw contained in the motorized ceiling supply unit, a component of the Harmony EMS system. The ceiling supply unit controls the motorized adjustment of … |
From FDA enforcement reports that name this device, by a company paying for it. Class I is the most serious recall and Class III the least.
The full lists, detailed tables and downloads are in the Data view.