CELLEX
Medical device: Photopheresis system blood set. 1 company paid 56 providers $218K in 2025 payments naming it.
- Medical device
- Paid for by Therakos Llc
- FDA Class 3
Companies paying for it (2025)
- THERAKOS LLC$218K
Safety record
- FDA recalls naming it2
- Device problem reports2,294
- FDA risk classClass 3 (highest)
Reports to FDA don't prove the product caused the event.
About this device
A collection of devices used as part of a photopheresis system for extracorporeal photoimmunetherapy to treat immune disorders, especially cutaneous T-cell lymphoma (CTCL). It typically consists of tubing (patient and fluid lines), fluid/blood component bags, a dedicated centrifuge bowl, a photoactivation chamber, connectors, and clamps. It conducts blood from the patient to the system's main unit, aids in blood processing, and returns leukocyte-enriched and untreated components of the blood after irradiation. This is a sterile, single-use device.
- Brand
- CELLEX
- Company
- Therakos LLC
- Model described
- Cellex Procedural Kit U.S. (CLXUSA)
- Device type
- Photopheresis system blood set
- FDA product code
- LNR · System, Photopheresis, Extracorporeal
- FDA class
- Class 3 (highest risk)
- Specialty
- Unknown
- Sold
- by prescription
- Status
- In Commercial Distribution
- GUDID record
- 00705030000050
FDA's device database (GUDID) record of the device identifier named most in the payments: one model of the product line.
FDA recalls
2 recalls naming it since 2004 (Class I, the most serious: 0; Class II: 2; Class III: 0).
| Started | Recall | Class | Firm | Product | Reason |
|---|---|---|---|---|---|
| 2021-10-04 | Z-0212-2022 | Class II | Therakos, Inc. | THERAKOS CELLEX Photopheresis Procedural Kit PRODUCT CODE: CLXUSA | Product was released prior to all testing being completed. If used and a drive tube leak were to occur, may cause illness or injury. |
| 2015-12-21 | Z-1322-2016 | Class II | Therakos Inc | The THERAKOS CELLEX Photopheresis System is a photoimmune therapy. Catalog CLXUSA. Manufacturing lot D342 UDI: 20705030200003 The system designed to separate the patient's blood into various fractions and collect the white blood cell … | The Mallinckrodt (Therakos) post-market monitoring process detected an increased trend in tubing leaks within the pump tubing organizer, associated with a portion of Kits from Lot D 342. |
From FDA enforcement reports that name this device, by a company paying for it. Class I is the most serious recall and Class III the least.