Axios
Medical device: Implantable transenteric drainage tube. 1 company paid 755 providers $225K in 2025 payments naming it.
- Medical device
- Paid for by Boston Scientific Corporation
- FDA Class 2
Companies paying for it (2025)
Safety record
- FDA recalls naming it26
- Device problem reports2,790
- FDA risk classClass 2 (moderate)
Reports to FDA don't prove the product caused the event.
About this device
A non-bioabsorbable tube intended to be endoscopically implanted transmurally between the gastrointestinal (GI) tract and a pancreatic pseudocyst or the biliary tract for drainage. It is a flanged stent-like structure made of metal which is covered/lined with a synthetic polymer material (e.g., silicone). It is typically expanded in situ (e.g., with a balloon catheter or self-expands) and disposable devices to assist implantation, with or without electrosurgical functionality, may be included with the device.
- Brand
- Axios™
- Company
- BOSTON SCIENTIFIC CORPORATION
- Model described
- Stent and Delivery System (M00553740)
- Device type
- Implantable transenteric drainage tube
- FDA product code
- PCU · pancreatic stent, covered, metallic, removable
- FDA class
- Class 2 (moderate risk)
- Specialty
- Gastroenterology, Urology
- Sold
- by prescription
- Implant
- Yes
- Status
- In Commercial Distribution
- GUDID record
- 08714729904625
FDA's device database (GUDID) record of the device identifier named most in the payments: one model of the product line.
FDA recalls
26 recalls naming it since 2004 (Class I, the most serious: 6; Class II: 20; Class III: 0).
| Started | Recall | Class | Firm | Product | Reason |
|---|---|---|---|---|---|
| 2025-12-19 | Z-1163-2026 | Class I | Boston Scientific Corporation | *HOT AXIOS Stent and Electrocautery-Enhanced Delivery System 20mm x 10mm; Material Number (UPN): M00553560; | Increased reports of stent deployment and expansion issues. The most common outcome reasonably foreseeable resulting from difficulty deploying the stent is prolongation of the procedure to exchange the device for a new one. The most … |
| 2025-12-19 | Z-1162-2026 | Class I | Boston Scientific Corporation | *HOT AXIOS Stent and Electrocautery-Enhanced Delivery System 8mm x 8mm; Material Number (UPN): M00553530; | Increased reports of stent deployment and expansion issues. The most common outcome reasonably foreseeable resulting from difficulty deploying the stent is prolongation of the procedure to exchange the device for a new one. The most … |
| 2025-12-19 | Z-1161-2026 | Class I | Boston Scientific Corporation | HOT AXIOS Stent and Electrocautery-Enhanced Delivery System 6mm x 8mm; Material Number (UPN): M00553520; | Increased reports of stent deployment and expansion issues. The most common outcome reasonably foreseeable resulting from difficulty deploying the stent is prolongation of the procedure to exchange the device for a new one. The most … |
| 2025-12-19 | Z-1160-2026 | Class I | Boston Scientific Corporation | AXIOS Stent and Electrocautery-Enhanced Delivery System - 8mm x 8mm; Material Number (UPN): M00553690; | Increased reports of stent deployment and expansion issues. The most common outcome reasonably foreseeable resulting from difficulty deploying the stent is prolongation of the procedure to exchange the device for a new one. The most … |
| 2025-12-19 | Z-1159-2026 | Class I | Boston Scientific Corporation | AXIOS Stent and Electrocautery-Enhanced Delivery System - 6mm x 8mm; Material Number (UPN): M00553680; | Increased reports of stent deployment and expansion issues. The most common outcome reasonably foreseeable resulting from difficulty deploying the stent is prolongation of the procedure to exchange the device for a new one. The most … |
| 2025-12-19 | Z-1158-2026 | Class I | Boston Scientific Corporation | AXIOS Stent and Electrocautery-Enhanced Delivery System - 20mm x 10mm; Material Number (UPN): M00553660; | Increased reports of stent deployment and expansion issues. The most common outcome reasonably foreseeable resulting from difficulty deploying the stent is prolongation of the procedure to exchange the device for a new one. The most … |
| 2024-12-20 | Z-1037-2025 | Class II | Boston Scientific Corporation | HOT AXIOS Stent and Electrocautery- Enhanced Delivery System 15mmx15mm UPN: M00553570 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1036-2025 | Class II | Boston Scientific Corporation | HOT AXIOS Stent and Electrocautery- Enhanced Delivery System 20mmx10mm UPN: M00553560 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1035-2025 | Class II | Boston Scientific Corporation | HOT AXIOS Stent and Electrocautery- Enhanced Delivery System 15mmx10mm UPN: M00553550 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1034-2025 | Class II | Boston Scientific Corporation | HOT AXIOS Stent and Electrocautery- Enhanced Delivery System 10mmx10mm UPN: M00553540 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1033-2025 | Class II | Boston Scientific Corporation | HOT AXIOS Stent and Electrocautery- Enhanced Delivery System 8mmx8mm UPN: M00553530 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1032-2025 | Class II | Boston Scientific Corporation | HOT AXIOS Stent and Electrocautery- Enhanced Delivery System 6mmx8mm UPN: M00553520 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1031-2025 | Class II | Boston Scientific Corporation | AXIOS Stent and Delivery System 15mmx10mm UPN: M00553750 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1030-2025 | Class II | Boston Scientific Corporation | AXIOS Stent and Delivery System 10mmx10mm UPN: M00553740 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1029-2025 | Class II | Boston Scientific Corporation | AXIOS Stent and Electrocautery- Enhanced Delivery System 8mmx8mm UPN: M00553690 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1028-2025 | Class II | Boston Scientific Corporation | AXIOS Stent and Electrocautery- Enhanced Delivery System 6mmx8mm UPN: M00553680 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1027-2025 | Class II | Boston Scientific Corporation | AXIOS Stent and Electrocautery- Enhanced Delivery System 15mmx15mm UPN: M00553670 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1026-2025 | Class II | Boston Scientific Corporation | AXIOS Stent and Electrocautery- Enhanced Delivery System 20mmx10mm UPN: M00553660 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1025-2025 | Class II | Boston Scientific Corporation | AXIOS Stent and Electrocautery- Enhanced Delivery System 15mmx10mm UPN: M00553650 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
| 2024-12-20 | Z-1024-2025 | Class II | Boston Scientific Corporation | AXIOS Stent and Electrocautery- Enhanced Delivery System 10mmx10mm UPN: M00553640 | Reported Outer sheath distal black tip detaching from the device can remain around the stent saddle, preventing proper expansion, resulting in prolongation of the procedure to exchange the device for a new one. |
From FDA enforcement reports that name this device, by a company paying for it. Class I is the most serious recall and Class III the least.