APTIMA
Medical device: Human papillomavirus (HPV) high risk strain nucleic acid IVD, kit, nucleic acid technique (NAT). 3 companies paid 12,318 providers $965K in 2025 payments naming it.
- Medical device
- Paid for by Hologic Sales And Service, Llc, Gen-Probe, Inc. +1
- FDA Class 3
Companies paying for it (2025)
- HOLOGIC SALES AND SERVICE, LLC$478K
- GEN-PROBE, INC.$475K
- CYTYC CORPORATION$12K
Safety record
- FDA recalls naming it4
- Device problem reports1,054
- FDA risk classClass 3 (highest)
Reports to FDA don't prove the product caused the event.
About this device
A collection of reagents and other associated materials intended to be used for the qualitative and/or quantitative detection of nucleic acid from one or multiple high-risk strains of human papillomavirus (HPV) associated with cervical cancer, which may include types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66 and/or 68 in a clinical specimen, using a nucleic acid technique (NAT).
- Brand
- Aptima®
- Company
- Hologic, Inc.
- Model described
- Aptima® HPV Assay, 250 test, box 1 of 2 (2°C to 8°C box). (KIT, HPV, APTIMA, 250 TEST, REFRIG, IVD)
- Device type
- Human papillomavirus (HPV) high risk strain nucleic acid IVD, kit, nucleic acid technique (NAT)
- FDA product code
- OYB · Kit, rna detection, human papillomavirus
- FDA class
- Class 3 (highest risk)
- Specialty
- Unknown
- Sold
- by prescription
- Status
- In Commercial Distribution
- GUDID record
- 15420045500051
FDA clearance or approval
| Number | Kind | Device | Applicant | Decided |
|---|---|---|---|---|
| P100042 | PMA | APTIMA HPV ASSAY | Gen-Probe Incorporated | 2011-10-28 |
A 510(k) clearance means FDA found the device much like one already sold. A PMA approval means FDA reviewed clinical evidence, which it requires for high-risk devices.
FDA's device database (GUDID) record of the device identifier named most in the payments: one model of the product line.
FDA recalls
4 recalls naming it since 2004 (Class I, the most serious: 0; Class II: 3; Class III: 1).
| Started | Recall | Class | Firm | Product | Reason |
|---|---|---|---|---|---|
| 2026-02-18 | Z-1586-2026 | Class II | Hologic, Inc. | Brand Name: Aptima HPV Assay Product Name: Aptima HPV Assay Model/Catalog Number: 303585 Product Description: Aptima HPV assay Component: No | Due to product exhibiting potential to generate either invalid or false negative results. |
| 2023-12-15 | Z-0782-2024 | Class II | Hologic, Inc. | PANTHER FUSION System REF 9121010000 The Panther System is an integrated nucleic acid testing system which fully automates all steps necessary to perform Aptima assays from sample processing through amplification, detection, and data … | Due to potential false positive Flu B results when a sample was also SARS-CoV-2 positive. |
| 2023-09-14 | Z-1371-2024 | Class II | Hologic, Inc. | Aptima CMV Quant Assay, Reference numbers: AW-22600-001, AW-25509-001, and AW-26381-001 Amplification Reagent, Enzyme Reagent, Promoter Reagent, Amplification Reconstitution Solution, Enzyme Reconstitution Solution, Promoter Reconstruction … | Use of assay along with plasma specimen may result in error code which would invalidate sample. |
| 2014-04-17 | Z-1793-2014 | Class III | Gen-Probe Inc | APTIMA Urine Collection Kit; Catalog Number 301040, Lots 27231, 27232, 27233, and 27234. Product Usage: The APTIMA Urine Specimen Collection Kit for Male and Female Urine Specimens is for use with APTIMA assays. The APTIMA Urine … | Incorrect labeling was used on each pouch of the affected lots of APTIMA Urine Specimen Collection Kits. The outer box of the kits are identified correctly as "APTIMA Urine Collection Kits"; however, the inner pouches are incorrectly … |
From FDA enforcement reports that name this device, by a company paying for it. Class I is the most serious recall and Class III the least.
The full lists, detailed tables and downloads are in the Data view.