3DIMENSIONS
Medical device: Stationary mammographic x-ray system, digital. 2 companies paid 307 providers $159K in 2025 payments naming it.
- Medical device
- Paid for by Hologic Sales And Service, Llc, Hologic Inc
- FDA Class 3
Companies paying for it (2025)
Safety record
- FDA recalls naming it3
- Device problem reports231
- FDA risk classClass 3 (highest)
Reports to FDA don't prove the product caused the event.
About this device
A stationary assembly of devices designed to generate x-ray images of the breast using digital techniques for image capture and display. It is designed specifically to compress the breast during imaging and is intended to visually evaluate the anatomy and function of blood and lymphatic vessels within the breast. Often referred to as a digital mammography system (DMS) it is typically used for breast cancer screening or during biopsy procedures (e.g., placement of biopsy markers, stereotactic biopsy). It is designed to capture two-dimensional (2-D) x-ray images, however may include software …
- Brand
- 3Dimensions
- Company
- Hologic, Inc.
- Model described
- Hologic Clarity HD® (high resolution tomosynthesis) is a software driven digital breast tomosynthesis 3(D) imaging feature intended to improve image resolution on tomosynhesis slices and synthesized 2D images that will enhance image quality and user experience. (CLARITY HD SOFTWARE)
- Device type
- Stationary mammographic x-ray system, digital
- FDA product code
- OTE · Digital breast tomosynthesis
- FDA class
- Class 3 (highest risk)
- Specialty
- Unknown
- Sold
- by prescription
- Status
- In Commercial Distribution
- GUDID record
- 15420045507272
FDA clearance or approval
| Number | Kind | Device | Applicant | Decided |
|---|---|---|---|---|
| P080003 | PMA | SELENIA DIMENSIONS FULL FIELD DIGITAL MAMMOGRAPHY SYSTEM | Hologic, Inc. | 2011-02-11 |
A 510(k) clearance means FDA found the device much like one already sold. A PMA approval means FDA reviewed clinical evidence, which it requires for high-risk devices.
FDA's device database (GUDID) record of the device identifier named most in the payments: one model of the product line.
FDA recalls
3 recalls naming it since 2004 (Class I, the most serious: 0; Class II: 3; Class III: 0).
| Started | Recall | Class | Firm | Product | Reason |
|---|---|---|---|---|---|
| 2026-04-08 | Z-2168-2026 | Class II | Hologic, Inc | 3DIMENSIONS MAMMOGRAPHY SYSTEM; Model Numbers: 3DM-SYS-INTL2D, 3DM-SYS-INTL2D-MOB, 3DM-SYS-INTL2D-NS, 3DM-SYS-INTL3D, 3DM-SYS-INTL3D-MOB, 3DM-SYS-INTL3D-NS, 3DM-SYS-STD, 3DM-SYS-STD-MOB, 3DM-SYS-STD-NS. | Complaints have been received of systems developing loose, missing, or broken internal bolts over time. |
| 2024-08-19 | Z-3248-2024 | Class II | Hologic Inc | Selenia Dimensions/ 3Dimensions-Digital breast tomosynthesis Software Version Dimensions 1.12.0 and 3Dimensions 2.3.0 system software as follows Model/Catalog Number: 1. ASY-16824 FMI UPGRADE KIT, DIMENSIONS 1.12.0.3 SYSTEM SOFTWARE … | Identified an issue with Selenia Dimensions 1.12.0 and 3Dimensions 2.3.0 system software when used in combination with C-View software in which the quality of the final C-View synthesized 2D image is impacted and may appear blurry and … |
| 2023-01-16 | Z-1144-2023 | Class II | Hologic, Inc. | Hologic 3Dimensions/Selenia Dimensions Models: RM-SDM-00001-3D SDM-00001-2D SDM-00001-3D SDM-05000-3D3 SDM-05000-2DC SDM-00001-M3D SDM-05000-3DC SDM-SYS-6000-3D SDM-05000-2D3 SDA-SYS-3000-2D SDM-00001 SDM-SYS-9000-2D … | C-Arm unexpected movement may cause blunt trauma should the tube arm impinge upon an individual |
From FDA enforcement reports that name this device, by a company paying for it. Class I is the most serious recall and Class III the least.
The full lists, detailed tables and downloads are in the Data view.