Cathedral Health Care Center
Nursing home in Jasper, IN, 65 certified beds. 1 clinician lists an affiliation with it.
- Medicare certified
- CMS Certification Number 155720
Nursing home Ownership: For profit - Corporation65 certified beds
How CMS rates it
Overall
★★★★★
4 of 5 stars · CMS overall nursing home rating
Health inspections
★★★★★
4 of 5 stars · State inspections
Staffing
★★★★★
3 of 5 stars · Nurse staffing hours
Quality measures
★★★★★
4 of 5 stars · Resident care measures
Medicare Care Compare.
Inspections and penalties
Health deficiencies
1
latest inspection cycle, last inspected Jul 24, 2025
Harm or immediate jeopardy
0
health deficiencies G–L, last three cycles
Fines
None
in the last three years
Payment denials
None
Medicare stopped paying for new admissions
Deficiencies by inspection cycle
| Cycle | Health | Of them harm or jeopardy | From complaints | Fire safety |
|---|---|---|---|---|
| 1 (latest) | 1 | 0 | 0 | 1 |
| 2 | 7 | 0 | 0 | 6 |
| 3 | 9 | 0 | 2 | 20 |
Health deficiencies by scope and severity
| Severity | Isolated | Pattern | Widespread |
|---|---|---|---|
| Immediate jeopardy to health or safety | 0 (J) | 0 (K) | 0 (L) |
| Actual harm | 0 (G) | 0 (H) | 0 (I) |
| Potential for more than minimal harm | 15 (D) | 2 (E) | 0 (F) |
| Potential for minimal harm | 0 (A) | 0 (B) | 0 (C) |
The most serious and the newest citations
| Inspected | Deficiency | Scope and severity | Status |
|---|---|---|---|
| Jul 24, 2025 Fire safety |
K0921 Ensure that testing and maintenance of electrical equipment is performed. Gas, Vacuum, and Electrical Systems Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Aug 15, 2025) |
| Sep 13, 2024 Fire safety |
K0345 Have approved installation, maintenance and testing program for fire alarm systems. Smoke Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Oct 11, 2024) |
| Sep 11, 2023 Fire safety |
E0004 Develop and maintain an Emergency Preparedness Program (EP). Emergency Preparedness Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Nov 1, 2023) |
| Sep 11, 2023 Fire safety |
E0013 Develop Emergency Preparedness policies and procedures. Emergency Preparedness Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Nov 1, 2023) |
| Sep 11, 2023 Fire safety |
E0029 Develop a communication plan. Emergency Preparedness Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Nov 1, 2023) |
| Sep 11, 2023 Fire safety |
E0036 Establish emergency prep training and testing. Emergency Preparedness Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Nov 1, 2023) |
| Sep 11, 2023 Fire safety |
K0222 Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements. Egress Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Nov 1, 2023) |
| Sep 11, 2023 Fire safety |
K0321 Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. Smoke Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Nov 1, 2023) |
| Sep 11, 2023 Fire safety |
K0353 Inspect, test, and maintain automatic sprinkler systems. Smoke Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Nov 1, 2023) |
| Sep 11, 2023 Fire safety |
K0761 To conduct inspection, testing and maintenance of fire doors by qualified individuals. Miscellaneous Deficiencies |
Potential for more than minimal harm, widespread (F) | Deficient, Provider has date of correction (Nov 1, 2023) |
| Sep 13, 2024 Health |
F0880 Provide and implement an infection prevention and control program. Infection Control Deficiencies |
Potential for more than minimal harm, pattern (E) | Deficient, Provider has date of correction (Oct 12, 2024) |
| Sep 13, 2024 Fire safety |
K0200 Meet other general requirements. Egress Deficiencies |
Potential for more than minimal harm, pattern (E) | Deficient, Provider has date of correction (Oct 11, 2024) |
| Sep 13, 2024 Fire safety |
K0321 Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system. Smoke Deficiencies |
Potential for more than minimal harm, pattern (E) | Deficient, Provider has date of correction (Oct 11, 2024) |
| Sep 13, 2024 Fire safety |
K0353 Inspect, test, and maintain automatic sprinkler systems. Smoke Deficiencies |
Potential for more than minimal harm, pattern (E) | Deficient, Provider has date of correction (Oct 11, 2024) |
| Sep 13, 2024 Fire safety |
K0372 Ensure smoke barriers are constructed to a 1 hour fire resistance rating. Smoke Deficiencies |
Potential for more than minimal harm, pattern (E) | Deficient, Provider has date of correction (Oct 11, 2024) |
| Sep 13, 2024 Fire safety |
K0920 Ensure proper usage of power strips and extension cords. Gas, Vacuum, and Electrical Systems Deficiencies |
Potential for more than minimal harm, pattern (E) | Deficient, Provider has date of correction (Oct 11, 2024) |
| Jul 24, 2025 Health |
F0656 Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured. Resident Assessment and Care Planning Deficiencies |
Potential for more than minimal harm, isolated (D) | Deficient, Provider has date of correction (Aug 15, 2025) |
| Sep 13, 2024 Health |
F0580 Immediately tell the resident, the resident's doctor, and a family member of situations (injury/decline/room, etc.) that affect the resident. Resident Rights Deficiencies |
Potential for more than minimal harm, isolated (D) | Deficient, Provider has date of correction (Oct 12, 2024) |
Every inspection (8)
- Jul 24, 2025 · Health · 1 deficiency, most serious D
- Jul 24, 2025 · Fire safety · 1 deficiency, most serious F
- Sep 13, 2024 · Health · 7 deficiencies, most serious E
- Sep 13, 2024 · Fire safety · 6 deficiencies, most serious F
- Aug 23, 2024 · Health · 1 deficiency (1 from complaints), most serious D
- Jan 9, 2024 · Health · 1 deficiency (1 from complaints), most serious D
- Sep 11, 2023 · Health · 7 deficiencies, most serious E
- Sep 11, 2023 · Fire safety · 20 deficiencies, most serious F
From Medicare Care Compare, updated by CMS on October 1, 2026. State inspectors check every nursing home about once a year and after complaints. Letters A to L rate each problem, and G to L mean residents were harmed or at serious risk.
Location
© OpenStreetMap contributors
520 W 9Th St
Jasper, IN 47546
The full lists, detailed tables and downloads are in the Data view.